Two questions, both answered from published tables. Use the larger answer as your starting point. An electrician still sizes the generator from your actual loads.
For about 2,000 sq ft, published guides suggest about 10 to 14 kW. To run essentials plus central air and a water heater, guides suggest 14 to 18 kW, with a typical generator cost of about $4,000 to $5,500 before installation. Go with the larger of the two. This is a rough guide from published tables, not a load calculation. An electrician sizes the generator from your actual loads. This is a typical published national range, not a quote. Rough estimate only. Your final price comes after an electrician sees the job.
Both tables below are on the page even when JavaScript is off.
How generator sizing works
Generators are rated in kilowatts. A 10 kW generator supplies 10,000 watts. To size one, list what you want running during an outage and add up the wattage, including the extra surge some motors need to start. Published guides offer two shortcuts: home size, and what you want to keep on. This tool shows both. Use the larger answer as your starting point.
The home size shortcut is a band, not a promise that every house of that size needs the same generator. A small house with electric heat can need more than a larger house with a gas furnace. That is why the second question asks what you want to keep running, and why the starting point is the larger of the two answers.
Common appliance wattages
Published figures list a refrigerator at about 600 watts, a large dehumidifier at about 700 watts, a large window air conditioner at about 1,400 watts, a water heater at 3,000 to 4,500 watts, and an electric furnace at 5,000 to 25,000 watts. (Source: Angi, updated Sep 1, 2026)
Motors such as a well pump, a sump pump, and a furnace fan draw extra watts for a moment when they start. A generator that looks big enough for the running watts can still trip if it cannot cover that surge. The published bands already leave room for that. A load list from your panel is still the real sizing step.
Sioux Falls winters
In a winter outage, the furnace fan, sump pump, fridge, and, on acreages, the well pump are usually the priority. Homes with electric heat need far more capacity than homes with a gas furnace.
Blizzards and ice storms are when backup power matters most around Sioux Falls, Hartford, Canton, and Dell Rapids. A gas furnace still needs the fan. An acreage on a well still needs the pump. Tell us which of those have to stay on, and we will size from those loads instead of from square footage alone.
Portable or standby
A portable generator with a transfer switch or interlock can run a few essential circuits. A standby generator starts on its own and can run most or all of the house. See generator installation for costs, and transfer switches.
Generac units are one of the standby brands these published cost bands cover. The size you need comes from the loads, not from the brand. Installation, the pad, the fuel connection, and the transfer switch sit on top of the generator price.
Get it sized right
Too small and it trips under load; too big and you pay for capacity you never use. Call (605) 250-4838 and we will size it from your real loads.
Typical published size and cost ranges
By home size
| Home size | Typical size range |
|---|---|
| Home sizeabout 1,000 sq ft | Typical size range6 to 9 kW |
| Home sizeabout 1,500 sq ft | Typical size range7 to 10 kW |
| Home sizeabout 2,000 sq ft | Typical size range10 to 14 kW |
| Home sizeabout 2,500 sq ft | Typical size range12 to 16 kW |
| Home size3,000 sq ft or more | Typical size range16 to 20 kW or more |
By what you want to run
| Coverage | Typical size | Typical published generator cost |
|---|---|---|
| CoverageEssentials: fridge, freezer, sump pump, well pump, furnace fan, some lights | Typical size7.5 to 10 kW | Typical published generator cost$2,000 to $3,500 |
| Coverageessentials plus central air and a water heater | Typical size14 to 18 kW | Typical published generator cost$4,000 to $5,500 |
| Coveragemost of the house, including larger appliances | Typical size20 to 24 kW | Typical published generator cost$5,000 to $6,500 |
Typical published national ranges, not a quote. Rough estimate only. Your final price comes after an electrician sees the job.
Source: Angi, whole house generator cost, updated Sep 1, 2026
Get my quote
Send the home size and what you want running. A local electrician will size it from the real loads. This form goes to service@siouxfalls-electrician.com.
Questions about generator size
What size generator do I need for a 2,000 square foot house?
Published sizing guides suggest about 10 to 14 kW for a 2,000 square foot home. If you want central air and an electric water heater running too, plan on 14 to 18 kW.
Will a 7,500 watt generator run my house?
Published guides say a 7,500 watt generator can cover essentials like a refrigerator, freezer, well pump, and lighting circuits, but not high demand items like an electric water heater or furnace.
How much does a 20 kW to 24 kW generator cost?
Published national figures put the generator itself at about $5,000 to $6,500, before installation, the pad, and the transfer switch.